Loading... Please wait...
BONDASCOPE 3100
The follow-on to the famed capability of the BondaScope2100, the BondaScope 3100 re-defines the meaning of “Full Featured” and “Multi-Mode” Composite Bond Tester housed in a larger “Ruggedized” aluminium case featuring a High Speed, 5.7” dia. QVGA, Hi-Bright, EL display featuring NDT Systems “X-or” Digital Phosphor, true persistence control … not simply a screen clear.
In addition the BondaSCope 3100 incorporates all the features above including Resonance Impedance Plane Mode, adding an adjustable, Hi-Energy fixed frequency Mechanical Impedance Analysis Mode (MIA) as well as a Swept Frequency MIA (SweepMI) Mode bringing the MIA mode to a more useful and interpretive purpose. Specific to the BondaScope 3100 is the High-Energy, Swept Frequency Pitch-Catch Mode.
Specifications -
Modes: Resonance (RF & Flying Dot); Pitch Catch (Tone Burst - Adjustable Frequency, Cycles and Amplitude) High Energy Pulsed Mode. Swept Frequency; Mechanical Impedance Analysis (MIA) Fixed and Swept Frequency... Industry First.
Display: 240x320 QVGA, 5.7" Diag High Bright EL. Probe Connector: Standard 11 Pin Fischer - Adapts to other available probes.
Frequency Range: 250 - 1.5MHz Probe and setup specific
Alarm: Box, Polar and up to 8 individual and individually sizable "Ring Gates" centered at stored Reference Dot locations in Impedance Plane operation. Positive or negative operation.
Storage: 100 Setups & 250 Screens w/ Real Time Date and Time Stamp. Full 32 character Alpha-Numeric File naming with 8 lines of 32 characters for user comment or instruction.
Master Supervisor Setup and Lockout: Supervisory mode allows individual instrument setups parameters to be totally locked, totally unlocked or allow the user to operate ONLY within the supervisory defined parameters. For instance, allow frequency change within 24-28KHz and Gain within 35-40dB and no change to alarm etc. Available to EVERY instrument setup parameter! Industry First
Inputs & Outputs: 0-5VDC - Alarm - Positive or Negative - Latched or Momentary, Phase, Amplitude, X and Y Dot Location - Rate continuous in Resonance and Mechanical Impedance, USB
Power: Single Li-Ion High Energy Battery Smart Cell. In Battery Microprocessor reports current charge and time to empty - Approx 8 Full Hours Operation
Conditioning Fast Charger provides extended battery life and charge condition calibration. 85-240VAC Auto Sensing
Dimensions: 9.25H x 5.5W x 2.9D - Weight - 5Lbs
Operating Temperature: -10° to 140°F
Accessories and Options Include -
For further information please visit: www.ndtsystems.com